SYSTEM SPECIFICATIONS
System Weight:
External Sub - Systems: 17 pounds
Power Box 6 pounds
Internal Display 3 pounds
Cables 4 pounds
Crossbar Assembly Length: 63.25, 32, 51.25in. ± 2in.
Mechanical Mounting: Strut bracket mount
Installation Time: 2 hours, typical
External Housing Rating: NEMA 3S and IP 54
Display Housing Rating: Spill proof
External Sub -
System Materials: Aluminum and plastic
Environmental PCB Control: Conformal PCB coating
Operating Temperature
Range: - 22°F to 122°F
Operating Humidity Range: 5 to 100 % RH, non-condensing